Products > Accessories

DISPENSING TRANSFER PUMPS

Allenair Manufactures Dispensing & Transfer Pumps

  • For the pumping and transfer of most liquids.
  • Accurately dispense various food products and chemicals.
  • Pumps can be made in a number of variations, which can
    include different seal and pump materials depending on
    application requirements.

CALL FOR APPLICATION ASSISTANCE

 
 

ALLENAIR CORP.

QUALITY FIRST...TODAY


ALLENAIR CORP.
255 EAST SECOND STREET
MINEOLA, NY 11501
Phone: 516-747-5450
Fax: 516-747-5481
E-mail: sales@allenair.com
1

Description:

The Allenair pumps are designed around our tandem cylinder design joining two cylinders together with a common head and rod. The total pump unit is divided into two sections; the drive section and the pump section. By utilizing a four-way valve to operate the drive cylinder, the common rod and pump piston will move in unison, creating suction on the up stroke and pressure on the down stroke. An example of this action is that of a syringe.

PUMPING CORROSIVE LIQUIDS.

Used to pump deionized water, the photograph to the right depicts an EVTP model pump with an all stainless steel pump chamber, utilizing a VCR automatic reciprocating Valve in Head drive cylinder.


For More Information on PUMPING CORROSIVE LIQUIDS


EVTP 2 X 6 VCR CS

Corrosive Liquid Pumps

DISPENSING FOOD PRODUCTS.

Used to dispense lard or high viscosity liquids the photograph to the right depicts an ALL 300 Series Stainless Steel SSETP model pump. This pump utilizes an SA adjustment rod to produce a variable displacement chamber, with exceptional repeatability.


For More Information on DISPENSING FOOD PRODUCTS.


ETP 2-1/2 X 3 J2 SA CS

Food Service Pumps

DISPENSING PETROLEUM BASED PRODUCTS.

Used to dispense lubricating oil, the photograph to the right depicts an EVTP model pump. This pump utilizes a VSAT valve option to dispense a fixed volume of oil while maintaining the ability to adjust that volume using the SA adjustment rod.


For More Information on DISPENSING PETROLEUM BASED PRODUCTS.


EVTP 1-1/2 X 3 1/4 VSAT J2 CS

Volume Metric Pumps
2
DRIVE CYLINDER VALVES
EVTP
VALVE OPTIONS
3
“SA” ADJUSTABLE STROKE
EVTP VALVE OPTIONS
4
DRIVE CYLINDER VALVES





SINGLE SOLENOID

MODEL SVSR / VSST
This model incorporates a 4-way Single Solenoid Pilot Valve, air return. A maintained electrical contact is required to move the piston its full stroke. Breaking the electrical contact returns the piston to its original position. This Model is supplied with the piston normally retracted (electrical contact to extend piston) The standard solenoid operator is the AAS splice box housing. Voltages: 12, 24,120 & 240/60 AC and 6, 12 & 24VDC are standard.

SHOWN WITH NEMA 4 HOUSING
ORDERING CODE (JIC )

Viscous Liquid Pumps


SINGLE SOLENOID

MODEL VERR / VSESAT (AUTOMATIC RETURN)
This model incorporates a 4-way Single Solenoid Doubled Bleed Pilot Valve. A momentary (NOT continuous) electrical contact is required to move the piston its full stroke. Upon reaching its FULL stroke, the piston will automatically return to its original position. This model is supplied with the piston normally retracted (electrical contact will extend the piston) The standard solenoid operator is the AAS splice box housing. Due to internal construction and application requirements, there can be a loss of approximately 1/8” to 1/4” of stroke. Voltages: 12,24,120 & 240/60 and 6,12 & 24VDC are standard.


SHOWN WITH EXPLOSION-PROOF HOUSING
ORDERING CODE (AAX )

Viscous Liquid Pumps


DOUBLE SOLENOID

MODEL SDS / VDST
This model incorporates a 4-way Double Solenoid Pressure Pilot Valve. A momentary or maintained electrical contact applied to one solenoid will move the piston its full stroke. The piston will remain there under pressure until the other solenoid is energized, which will cause the piston to return to its original position. If a maintained contact is employed, the first solenoid must be de-energized before the other is energized. The standard solenoid operator, as shown is the AAS splice box housing. Voltages: 12, 24,120 & 240/60 AC and 6, 12 & 24VDC are standard.


For More Information on Viscous Liquid Pumps.

SHOWN WITH SPLICE BOX HOUSING
ORDERING CODE (AAS)

Viscous Liquid Pumps
5
DRIVE CYLINDER VALVES
CONTINUED





SINGLE PILOT

MODEL APSRR / VAPSRT
This model incorporates a 4-way Single Pressure Pilot Valve. A continuous pilot pressure applied to “IN” side of valve will move the piston its full stroke. When the pilot pressure is released, the piston will return to its original position. Pilot pressure is normally supplied through a 3-way N.C. Valve. Model is supplied with the rod normally retracted (pilot pressure to extend rod) pilot pressure must be at least 75% of the operating pressure.

Precision Dispensing Pumps


SINGLE PILOT

MODEL VARR / VSAT (AUTOMATIC RETURN)
This model incorporates a 4-way Double Bleed Pilot Valve. A momentary (NOT continuous) actuation of a Bleeder Valve is required to move the piston Its full stroke. Upon reaching its FULL stroke, the piston will automatically return to its original position. This model is supplied with the rod normally retracted (manual bleed to extend rod)
Due to internal construction and application requirements, there can be a loss of approximately 1/8” to 1/4” of stroke. Bleeder Valve Model BV100 is supplied on these models

Precision Dispensing Pumps


DOUBLE PILOT

MODEL AP / VAPT
This model incorporates a 4-way Double Pressure Pilot Valve. A momentary or maintained pilot pressure applied to one side of the valve will move the rod its full stroke. The piston will remain in that position under pressure until a pilot pressure is released and applied to the other side, which will cause the piston to return to its original position.
If a maintained pilot pressure is applied, it must be released before the other pilot pressure is applied. Pilot pressure must be at least 25% of the operating pressure.


For More Information on Precision Dispensing Pumps
Precision Dispensing Pumps
6
DRIVE CYLINDER VALVES
CONTINUED






AUTOMATIC RECIPROCATING

MODEL VCR (NOT AVAILABLE WITH “SA” OPTION)
This model incorporates a 4-way Double Bleed Pilot Valve. By means of Built-in Bleeder Valves and internal Cam Bosses.
This unit will automatically reciprocate as soon as air pressure is applied. It is recommended that a shut-off valve be mounted in the inlet line. Due to internal construction and application requirements, there can be a loss of approximately 1/4” to 1/2” of stroke. Minimum stroke available is 1”

Metering Pumps


MANUALLY OPERATED

The following 2 models incorporate a 4-way Manual Valve.


MODEL VH / VHT
This model requires manual operation
of the lever to both extend and
retract the piston.

Metering Pumps


MODEL VHSRR / VHSRT:

This model is lever operated
to extend the normally retracted piston. The valve is
equipped with a built-in spring return which automatically
returns the rod when lever is released .


For More Information on Metering Pumps
Metering Pumps
7
PUMP ACCESSORIES

HALL EFFECT SWITCHES (CSA “NRTL/C” Listed): ALLENAIR Hall Effect switches are designed to be used with our 1-1/2” thru 4” bore Pumps. The Pumps must be ordered with the “RM” option. All switches have an LED indicator light, nine (9) foot leads,a mounting bracket P/N RMB2 and an operating temperature range of - 22°F to +176 °F.


NOTES:
1) PNP output is Sourcing

2) NPN output is Sinking
All models require a mounting strap purchased
as a separate item based on the pump bore size.

MODELS H01-H04

REED SWITCHES (CSA “NRTL/C” Listed)
ALLENAIR Reed switches are designed to be used with our 1-1/2” thru 4” bore Pumps. The Pumps must be ordered with the “RM” option. All switches have nine (9) foot hook up cable. Operating temperature range is - 22°F to +176°F. Models R02, R04 and R05 have an LED indicator light. Models R02, R03, R04 and R05 have MOV surge suppression.





Models R01 - R04 include mounting bracket P/N RMB2.
Order mounting strap based on cylinder bore size as shown below.
Model R05 supplied with a universal mounting bracket and strap covering all bore sizes (1-1/2 thru 4”) P/N RMB1



8
PUMP ACCESSORIES
REED SWITCHES (Models R01 Thru R04)
Model R05 supplied with a universal mounting bracket and strap covering all bore sizes (1-1/2 thru 4”) P/N RMB1

MODELS R01- R04

MODEL R05

MOUNTING BRACKET DIMENSIONS

*ADD SS TO THE PART No. FOR STAINLESS STEEL
EXAMPLE: SSA-232

MOUNTING NUTS Mounting Nuts are supplied with the Foot Mounts and are included in the price of the Mounts. However,
they may be purchased as a separate item.




For More Information on Piston Pumps and Self Priming Pumps

*ADD SS TO THE PART No. FOR STAINLESS STEEL
EXAMPLE: SSA-214

9
DIMENSIONS
EVTP







* LARGEST PORT AVAILABLE (LPA)
1/2 N.P.T. WITH STAINLESS STEEL HEADS
** BRASS ”BU” TUBING INCREASE “C” DIM BY 1/16”


For More Information on Air Operated Pumps and Power Pumps
10
DIMENSIONS
ETP & EVTP PUMPS
“SA” ADJUSTABLE STROKE





* LARGEST PORT AVAILABLE (LPA)
1/2 N.P.T. WITH STAINLESS STEEL HEADS
** BRASS “BU” TUBING INCREASE “C” DIM BY 1/16”

11

MISCELLANEOUS INFORMATION

ALLENAIR PUMP DISPLACEMENTS VOLUMES



Drive Cylinder Air Consumption

This chart is used for calculating the air consumption of the pump drive cylinder to
determine the total volume of air required to meet a given cycle rate. The values shown
are for 100 P.S.I.


Example:

Total air consumption of a 2" bore drive cylinder with a 6" stroke operating at 10 cycles
per minute (20 strokes per minute):
6" Stroke x 0. 0142 (SCFM Inch Stroke) = 0.0852 SUM
0.0852 SCFM Stroke x 20 Strokes Per Min. = 1.704 SCFM



PUMP CURVE AT MAXIMUM PISTON VELOCITY

These figures are based on the maximum piston velocity the drive cylinder may
achieve pumping on one side only with a no load condition operating at 100
P.S.I for one minute at the Maximum cycle rate for the VCR cylinder model.

13

General Properties of Allenair's Seal Materials

Temperature ratings and chemical compatibilities shown below are for comparisons.See specific O-ring
presentations for exact specifications. NR=Not recommended.

VISCOSITY CHART


Pressure to Head Conversion formula

Liquids have specific gravities typically ranging from 0.5 to 1.8. Water is the benchmark with a specific gravity of 1.0. this benchmark and the resultant calculations are considered to be in "feet absolute." Head (ft) = Pressure (PSI) X 2.31/ Specific Gravity This formula is based on the fact that one foot of water exerts .4333 lbs of pressure at one foot. This converts to one lb. of pressure at 2.31 ft.


  • sg. = specific gravity
  • pressure = pounds per square inch
  • head = feet

Pressure = head x sg.
2.31


Head = pressure x 2.31
sg

14

TYPICAL PUMP CIRCUITS

Allenair pumps may be used as an
Alternative For many of these pumps types.

  • Air Operated Pumps
  • Direct-Acting Pumps
  • Dosing Pumps
  • Metering Pumps
  • Piston Pumps
  • Plunger Pumps
  • Pneumatic Pumps
  • Positive Displacement Pumps
  • Reciprocating Pumps
  • Simplex Plunger Pumps
  • Syringe Pumps
  • Viscous Liquid Pumps
  • Volume Metric Pumps
  • Industrial Dispensing Pumps
  • Sanitary Pumps
  • Self-Priming Pumps
  • Power Pumps
  • Precision Dispensing Pumps
  • Diaphragm Pumps




15

ALLENAIR CORP. 255 EAST SECOND ST. MINEOLA, NY 11501 USA
TELEPHONE: 516-747-5450 FAX: 516-747-5481

For ALLENAIR distribution in the USA and Canada,
Visit our Web Site at: www.allenair.com

ALLENAIR CORP. ASSUMES NO RESPONSIBILITY FOR ERRORS OR OMISSIONS

16